Seawater-Cooled Condensers With Reverse-Cycle Heating
Description
Available in capacities from 20,000 to 48,000 BTU/hr, Type R remote condensing units represent the next generation of seawater-cooled, reverse-cycle heat pumps for cooling and heating in marine applications. Models up to 36,000 BTU/hr use reciprocating compressors, while the 48K units use scroll compressors.These condensing units can be installed with up to two Cruisair cooling units, where the total cooling unit capacity is equal to the condensing unit capacity. Some applications may allow three cooling units on one condenser; contact the Cruisair Applications department for assistance in design, prior to installation. In the cooling mode, full performance is available in seawater up to 90°F (32°C). In reverse-cycle heating, the unit will provide heat in seawater as low as 40°F (4.4°C).
The high-efficiency compressors deliver full capacity at lower amperages. The newly designed, one-piece electrical box with 3 ft. (0.9 m) cable can be remote mounted simply by removing one screw (RN models have a secondary box). Additional service ports allow ease of charging and servicing. The one-piece chassis/pan has two drain locations, and hold-down brackets secure all four corners, allowing easier installation and removal. The Type R condenser is designed as a drop-in for the older F type, with few modifications.
R type units are designed for installation in the vessel’s engine room or other mechanical space. The unit is not affected by moisture, normal vibration, or ambient temperatures up to 140°F (60°C). No ventilation is required.
Three different series of Type R units are available, depending on what type of control is desired. Standard R units utilize the SA3 3-knob rotary switch assembly, RX units are controlled by the SMX II microprocessor, and RN models use SMX Net microprocessors. The SMX units include the respective SMX II or SMX Net power/logic boards. In addition, an SMXir or the new SMXht keypad/ display, a CXP connecting cable, and a TSEP temperature sensor must be purchased separately. If networking RN units, CNP network cables are also needed.
Key Benefits
- Higher efficiency compressors at lower amperages
- Service ports on refrigerant lines and base valves
- Compressor vibration-isolation mounts minimize noise and vibration
- Condensate drain pan with front and rear drain stems
- Environmentally safe R-417A refrigerant
- Condensate drain pan with front and rear drain stems
- Corner mounting brackets for easier installation
- High- and low-pressure switches
- Electrical box can be mounted remotely
- Optional seawater coil manifolds
- Additional vibration isolation kit available
- Charged, tested, and leak checked at the factory